{"product_id":"d-mistify-practice-video-assessment-kit","title":"d.MISTIFY Practice Video Assessment Kit","description":"\u003cdiv class=\"page\" title=\"Page 10\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"section\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"layoutArea\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"column\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"page\" title=\"Page 10\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"section\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"layoutArea\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"column\" data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan\u003ePractice Video Assessment Kit contains:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan\u003e3x d.MISTIFY Pro Data Capture Kits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan\u003e1x set of additional assorted d.MISTIFY Mirrors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan\u003e_______________________________________________________________________________\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003e\u003cspan\u003e3x d.MISTIFY Pro Data Capture Kit\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e3x d.MISTIFY ALD Unit\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e3x d.MISTIFY Nozzle\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e3x d.MISTIFY Adult Occlusal Mirror\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e3x d.MISTIFY Child Occlusal Mirror\u003c\/li\u003e\n\u003cli\u003e3x d.MISTIFY Straight Mirror\u003c\/li\u003e\n\u003cli\u003e3x d.MISTIFY Site Specific Mirror\u003c\/li\u003e\n\u003cli\u003e3x d.MISTIFY Arch Mirror\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e1x set of additional assorted d.MISTIFY Mirrors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003e1x d.MISTIFY Adult Occlusal Mirror\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e1x d.MISTIFY Child Occlusal Mirror\u003c\/li\u003e\n\u003cli\u003e1x d.MISTIFY Straight Mirror\u003c\/li\u003e\n\u003cli\u003e1x d.MISTIFY Site Specific Mirror\u003c\/li\u003e\n\u003cli\u003e1x d.MISTIFY Arch Mirror\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e________________________________________________________________________________\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDEVICE FOR CAPTURING INTRA-ORAL IMAGES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-mce-fragment=\"1\"\u003efor use in dental practices\u003c\/li\u003e\n\u003cli style=\"text-align: left;\" data-mce-fragment=\"1\"\u003efor use by patient at home\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe d.MISTIFY Pro Data Capture Kit features the Air and Light Dispersal (ALD) unit, which consists of a digital light array, in combination with a fan and two intraoral mirrors. This sophisticated device ensures that the surface of the intraoral mirrors (when attached) remains crystal clear and free of fog, due to the powerful light source and continual 2 speed turbo airstream. \u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\" data-mce-fragment=\"1\"\u003eThis results in easy-to-capture high-definition images and videos on either th\u003cstrong\u003ee in-\u003c\/strong\u003epractice or the patients’ own cell-phone\/digital camera. \u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eEither of the d.MISTIFY intraoral mirrors provided can be attached to the ALD Unit, and in addition, the d.Mistify ALD Nozzle ( bought separately ) can be connected to the ALD unit to provide an airstream that is powerful enough to clear saliva and debris from any targeted area.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe d.d.MISTIFY DCK is housed in an hygienic, high quality carrying case for storage in dental practice or in the home setting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstructions for Use \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCharging: \u003c\/strong\u003eThe device can be charged using the USB-C connection (the device is fully charged from zero in 20 minutes) and will operate continuously for up to 30minutes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAttaching the mirrors: \u003c\/strong\u003eThe underside of the d.Mistify device has a docking station specifically for attaching a mirror. Any of the 5 specific mirror shapes can be deployed for use by sliding down the narrower handle part of the mirror into the docking assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTurning on and off: \u003c\/strong\u003eThe d.MISTIFY has 2 buttons which have self-explanatory icons above them. The “fan only” button activates the air flow by turning the fan on. Press it twice to increase the airflow to the turbo speed. The “light and fan” button activates the airflow and digital light array simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCleaning: \u003c\/strong\u003eWipe down with a damp cloth.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStorage: \u003c\/strong\u003eAfter use, return the d.MISTIFY ALD unit to the original carrying case provided.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ed.MISTIFY ALD nozzle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ALD unit has a special nozzle that can be fitted to create a powerfully directed stream of air into any area of your mouth that needs to be dried, prior to capturing an image.\u003c\/p\u003e\n\u003cp\u003eIn addition, the nozzle delivers a beam of light which helps focus on the target area.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstructions for use \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe nozzle is fixed to the ALD unit by sliding the attachment arm of the nozzle into the backing plate of the device and seated fully. The air stream and light source are activated by pressing the relevant buttons on the ALD unit.\u003c\/p\u003e\n\u003cp\u003eThe nozzle and mirrors cannot be attached at the same time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"1122CORP","offers":[{"title":"Default Title","offer_id":45575575077013,"sku":"","price":499.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0247\/1585\/files\/shade_2_df432912-c879-4181-a2e1-d026d38200c3.png?v=1732504618","url":"https:\/\/1122corp.com\/products\/d-mistify-practice-video-assessment-kit","provider":"1122CORP","version":"1.0","type":"link"}